IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of  
combustion and ventilation air.  
It is the installer’s responsibility to comply with installation clearances specified on the  
model/serial rating plate. The model/serial rating plate is located on the underside of the  
cooktop burner base.  
It is recommended that a 600 CFM or larger vent hood be installed above the cooktop.  
It is not recommended that a microwave hood combination be mounted above the  
cooktop.  
The cooktop should be installed in a location away from strong draft areas, such as  
windows, doors and strong heating vents or fans.  
All openings in the wall or floor where cooktop is to be installed must be sealed.  
Cabinet opening dimensions that are shown must be used. Given dimensions are  
minimum clearances.  
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet  
supplier to make sure that the materials used will not discolor, delaminate or sustain other  
damage.  
Type of Gas  
Natural Gas:  
This cooktop is design-certified by CSA International for  
use with Natural gas or, after proper conversion, for use  
with LP gas.  
This cooktop is factory-set for use with Natural gas. To  
convert to LP gas, see the Gas Conversion instructions  
provided in the package containing literature. The model/  
serial rating plate located on the left underside of the  
cooktop burner base has information on the types of gas  
that can be used. If the types of gas listed do not include  
the type of gas available, check with the local gas supplier.  
LP Gas conversion:  
Conversion must be done by a qualified service technician.  
PRODUCT DIMENSIONS  
No attempt shall be made to convert the cooktop from the  
gas specified on the model/serial rating plate for use with a  
different gas without consulting the serving gas supplier. To  
convert to LP gas, use the LP gas conversion kit provided  
with the cooktop and see the “Gas Conversions” section.  
C
D
Gas Supply Line  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the  
cooktop location. A smaller size pipe on longer runs may  
result in insufficient gas supply. With LP gas, piping or  
tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas  
suppliers determine the size and materials used in the  
system.  
NOTE: Pipe-joint compounds that resist the action of LP  
gas must be used. Do not use TEFLON®† tape.  
E
Flexible metal appliance connector:  
A
B
If local codes permit, a new CSA design-certified, 4 - 5 ft  
(122 - 152.4 cm) long, ⁵⁄₈" (1.6 cm) or ³⁄₄" (1.9 cm) I.D.,  
flexible metal appliance connector may be used for  
connecting the cooktop to the gas supply line.  
A. 30" (76.2 cm) cooktop: 297⁄₈" (75.9 cm)  
C. Model/serial rating plate (located on the  
underside of the cooktop burner base)  
D. Island trim or optional backguard  
⁄₈  
7
36" (91.4 cm) cooktop: 35" (91.1 cm)  
7
48" (121.9 cm) cooktop: 47" (121.6 cm)  
Must include a shutoff valve:  
B. 36" (91.4 cm) long 3 prong grounding-type  
power supply cord  
E. 27  
70.5 cm)  
The supply line must be equipped with a manual shutoff  
valve. This valve should be located in the same room but  
external to the cooktop enclosure or cabinet. It should be  
in a location that allows ease of opening and closing. Do  
not block access to shutoff valve. The valve is for turning  
on or shutting off gas to the cooktop.  
A
B
B
A
C
C
G
E
A. Gas supply line  
Side View of Cooktop  
B. Shutoff valve “open” position  
C. To cooktop  
D
F
Electrical:  
A. 27  
70.5 cm)  
E. 22" (55.9 cm)  
F. 3⁵⁄₈" (9.2 cm)  
G. 1" (2.6 cm)  
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit  
is required. A time-delay fuse or circuit breaker is also  
recommended. It is recommended that a separate circuit  
serving only this cooktop be provided.  
C. 7⁷⁄₁₆" (18.8 cm)  
D. Gas inlet is located 1⁷⁄₈" (4.8 cm) from the back of  
the cooktop burner base and 4⁷⁄₈" (12.4 cm) in  
from left-hand side of the cooktop burner base.  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and  
Company.  
Page 1 of 2  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10526088A  
5/6/13  

Lenovo ThinkVision L2240p User Manual
Leupold Computer Monitor P4815 User Manual
LG Electronics LG Life Good Computer Monitor E2060T User Manual
Lincoln 1628 000 A User Manual
Lincoln Impinger Conveyorized Oven 3270 User Manual
Mabe Canada CLEAN MODELS SELF CLEAN SELF CLEAN JCBS640 User Manual
Marshall electronic V R241 DLW User Manual
Philips Brilliance 202P45 User Manual
Philips DVD Player DVP3879 User Manual
Philips Magnavox DVD850AT User Manual